Pipeline Integrity – Gas Line


Overview

An ILI report showed a number of low spots at three separate locations along a 100 feet stretch of gas pipeline. When the previous ILI was performed 7 years prior, these low spots did not exist. The operator not only wanted data to tell if the corrosion was episodic or in nature or active but also did not want to fix/repair the pipeline and did not want to perform another ILI on a shorter interval. After mapping the internal corrosion on the pipeline, installed sensors were deployed to monitor the low spots along the excavated line.


Application

Monitoring low spots instead of fix/repair

  • 30” natural gas transmission line nominal ~.300”
  • Low spots ranging from .120” to .240” – buried


Product Used

smartPIMS Modbus configuration with 8, 25 feet dual element probes permanently attached and buried to monitor “low spots” as identified by masses screening

  • Sensors were attached via epoxy and stopaq and buried
  • Enclosure used to house DSI and act as collection point for techs
  • Operator will vary frequency of manual readings


Share this post

Enhancing Efficiency and Safety: Xcel’s Nuclear Sites Harness the Power of JAWS 2.0

Foreign Objects Search and Retrieval (FOSAR) is a critical task in nuclear power plants, and having efficient tools like the JAWS 2.0™ is paramount to ensure safety and operational efficiency. Xcel’s nuclear sites, Monticello and Prairie Island, recently integrated the JAWS 2.0 ultimate kits into their FOSAR capabilities. These kits proved their effectiveness during routine maintenance at Monticello’s Spent Fuel Pool.