[vc_row full_width=”stretch_row” css=”.vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_column][vc_column_text]
Overview
Customer replaced lines on Atmospheric Tower due to amine corrosion (Chloride & HCL) issues. Installed sensors in TML ports circumferentially in areas where corrosion was seen previously to monitor corrosion rates.[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row” css=”.vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]
Application
- 24” line … insulated w/ TML ports, ~220F
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row” css=”.vc_custom_1490130495878{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_column][vc_column_text]
Product Used
- 1 smartPIMS cellular systems w/ 8 dual element probes
- Installation performed by rope access team at top of tower elevated ~250’
- Probes permanently installed in TML ports
- Monitoring interval: every 12 hours
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row” css=”.vc_custom_1490130502559{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}”][vc_column][vc_column_text]
Outcome
- Glean needed corrosion rate information without sending technicians
- Reduce safety measures due to elevation and rope access
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row” css=”.vc_custom_1490130522309{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_column][vc_media_grid element_width=”3″ gap=”20″ grid_id=”vc_gid:1490194672446-cfd07f22-3acc-8″ include=”2010,2011,2012,2013″][/vc_column][/vc_row]